NOYES OFL250-100 CALIBRATION and NOYES OFL250-100 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the NOYES OFL250-100 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another OTDR? Shop for Comparable Products on our   new OTDR page

 
   NOYES OFL250-100   Description / Specification:    
NOYES OFL250-100 Handheld OTDR, OPM, LS and VFL

The NOYES OFL250-100 1310/1550 nm single-mode OTDR and Laser Source, Optical Power Meter and Visual Fault Locator. Ideal for installation and maintenance testing of access and metro area networks operating at 1310 and/or 1550 nm. With short dead zone and 26 dB dynamic range performance, the OFL250-100 is ideal for troubleshooting single-mode fibers in local access and metro area networks. The OFL250-100 provides automatic and manual setup, automatic event detection, 12-hour battery life, internal data storage and USB connectivity. OTDR/OLS, OPM and VFL test ports are equipped with tool-free adapters, which can be changed in seconds. OTDR Specifications. Emitter Type: Laser. Available Wavelengths: 1310/1550 nm. Wavelength Tolerance: ±20/±20 nm. Dynamic Range (SNR = 1): 26 dB. Event Dead Zone: 1.5 m. Attenuation Dead Zone: 6.5/7 m. Pulse Widths: 5, 10, 30, 100, 300 ns, 1, 3, 10 ?s. Range Settings: 250 m to 256 km. Data Point Spacing: 12.5 cm (range <4 km), Range/16,000 (range >4 km). Group Index of Refraction (GIR): 1.4000 to 1.6000. Distance Uncertainty: ±(1 + 0.005 % x distance + data point spacing). OPM Specifications. Calibrated Wavelengths: 1310, 1490, 1550, 1625, 1650 nm. Detector Type: InGaAs. Measurement Range: +23 to -50 dBm. Accuracy @ -10 dBm: ±0.25 dB. Resolution: 0.01 dB. OLS Specifications. Emitter Type: Laser. Available Wavelengths: 1310/1550 nm. Wavelength Tolerance: ±20/±20 nm. Spectral Width (FWHM): 5 nm (maximum). VFL Specifications. Wavelength: 650 nm ±20 nm. Output Power (nominal): 0.8 mW.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the NOYES OFL250-100. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Coherence Length
Average distance over which superimposed waves lose their phase relationships

Linewidth
Linewidth is the width of a spectral line in terms of wavelength, wave number and frequency.

Power Flatness Versus Wavelength
When changing the wavelength at constant power setting and recording the differences between actual and displayed power levels, the power flatness is ± half the span (in dB) between the maximum and the minimum of the measured power levels.

Spectral Width
Spectral Width is the wavelength interval over which the magnitude of all spectral components is equal to or greater than a specified fraction of the magnitude of the component having the maximum value. In optical communications applications, the usual method of specifying spectral width is the full width at half maximum. This is the same convention used in bandwidth, defined as the frequency range where power drops by less than half (at most -3 dB).

Telecom Bands
Optical fiber communications typically operate in a wavelength region corresponding to one of the following Bands. O Band (original): 1260–1360 nm. E Band (extended): 1360–1460 nm. S Band (short wavelengths): 1460–1530 nm. C Band (conventional): 1530–1565 nm. L Band (long wavelengths): 1565–1625 nm. U Band (ultralong wavelengths): 1625–1675 nm


Please contact us for your NOYES OFL250-100 CALIBRATION and/or NOYES OFL250-100 Handheld OTDR, OPM, LS and VFL REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.